Troubleshooting
Fault indication and messages
Faults are displayed at different positions:
- Status LEDs on the AC-DC module.
- Status LEDs on the system control.
- On the web-based user interface.
- Via the Modbus.
Fault indication with the LEDs
LED | OFF | Blinking | Always ON |
---|---|---|---|
Red fault indicator (ALM) | normal | warning | fault |
Green operation indicator (OK) | stopped | running | starting |
Green power indicator (PWR) | no power input | / | power presents |
Messages
A distinction is made between alarm messages and warning messages
Alarm
Power operation is automatically shut off if serious errors occur. The PCS switches to the alarm state and outputs an alarm message. Power operation can only be restarted after the cause of the alarm has been removed and the alarm message has been reset
Warning
In case of less severe faults, the power operation is not interrupted, but a warning message is issued.